Abstract
We show the main results obtained
when applying the average theory to Zero Average Dynamic
control technique in a buck power converter with pulse-width
modulation (PWM). In particular, we have obtained the bound
values for output error and sliding surface. The PWM with
centered and lateral pulse configurations were analyzed. The
analytical results have confirmed the numerical and experimental
results already obtained in previous publications. Moreover,
through an important lemma, we have generalized the theory
for any stable second-order system with relative degree 2,
using properties related to transformations and stability of linear
systems.